Inventis mod. Flute: Inventis middle ear analyzer mod. Flute - Euroclinic | Medi-Care Solutions s.r.l

Inventis mod. Flute: Inventis middle ear analyzer mod. Flute

Product lines / ENT / Complementary equipment



2 years warranty

Description

Flute is a diagnostic middle ear analyzer, capable of performing incredibly fast and reliable automatic sequences of tympanometry and reflex threshold tests, as well as manual reflex and reflex decay tests, ETF test, and high frequency tympa-nometry. Great versatility, a user-friendly interface, advanced features and small size make Flute the ideal choice for a wide range of users, from hearing aid dispensers to clinics and hospitals.

Automatic test sequences

Speed up your middle-ear tests with the two available automatic exam sequences combined with special “fast” algorithms, all accurately developed to shorten the time needed for tympanometry and acoustic reflex assessments.

Ultimate hardware technology

Flute features an innovative pump technology for continuous air flow and a finely-designed probe. All combined to fit into an incredibly lightweight (just 2 kg) case.

The probe

Flute features an extremely light, small and sturdy metal probe, which can be very rapidly disassembled and cleaned. The probe is connected to the small Control Box, through which you can select the ear and start the exam.


Technical details - Sistemi di misura / Measurement systems


NAME VALUE
Man pump contr.available in Plus model
Range pressda -600 a +400 daPa
Range compl0.2 a 8.0 ml
Toni sonda226 Hz a 85 dB SPL - 1000 Hz a 75 dB SPL - (only mod. HF)



Technical details - Timpanometria / Tympanometry


NAME VALUE
ClassClass Ila (MDD 93/42)
StandardsTympan.: EN 60645-5 /ANSI 5339, Type 2 - Safety: EN 60601-1 - EMC: EN 60601-1-2
Weight2.0 kg
Dimension32 x 32 x 9 cm
Software compatibilityInventis Daisy o Noah (with dedicated moduls)
PC interfaceUSB (without driver)
Printer (optional)Integrated thermal
Resolution4,3", 480 x 272
ScreenColor graphical
Memory1 tympan. + 8 reflex + 4 decay record. per ear
Test ETFIntact eardrum (Plus e HF) - Perfored eardrum (solo HF)
Automatic testsQuick A e B (Seq. di temp. e rifl)
Stim. durationda 0.5 a 2.5 sec selecting, Reflex decay rif. 10 o 20 sec
Max intensity110 dB HL (ipsi); 120 dB HL (contra)
Stimuli250 (C), 500, 1k, 2k, 4k Hz - Solo Plus: 3k, 6k, 8k, (C) Hz, LPN, HPN, BBN, no stim.
Available testAutothreshold, Fixed intensity, Growing intensity-Only in Plus model: Manual test, Reflex decay Soglia autom.
StimulationIpsi e controlaterale
Press change50, 100, 200, 300 daPa/sec, AUTO
Type of testAutomatic and manual tympanometry